							Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems
GSO IEC 61557-15:2016 Files
				                	 
				                    No files for this standard are available in the store currently.
				                
  
			                
			                
								
																								
												
													Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
																								
											
										GSO IEC 61557-15:2016 Scope
									IEC 61557-15:2014 specifies requirements related to functional safety and is based on the IEC 61508 standard series for the realization of Insulation Monitoring Devices (IMD) as specified in IEC 61557-8 and for Insulation Fault Location Systems (IFLS) according to IEC 61557-9, according to phase 10 of the IEC 61508-1 lifecycle. These devices provide safety related functions for IT systems. This part of IEC 61557 is
- concerned only with functional safety requirements intended to reduce the functional risk during the use of IMDs and IFLSs;
- restricted to risks arising directly from the device itself or from several IMDs or IFLSs working together in a system; and
- intended to define the basic safety functions provided by the devices. This part of IEC 61557 does not
- deal with electrical safety according to IEC 61010-1 and the requirements of IEC 61557-8 and IEC 61557-9;
- cover the hazard and risk analysis of a particular use of the IMD or IFLS;
- identify all the safety functions for the application in which the IMD or IFLS is used; and
- cover the IMD or IFLS manufacturing process. Functional safety requirements depend on the application and should be considered as part of the overall risk assessment of the specific application. The supplier of IMDs and IFLSs is not responsible for the application. The application designer is responsible for the risk assessment and for specifying the overall functional safety requirements of the complete IT system and he should select the functional safety level (SIL) of the IMD and/or IFLS when their safety function is part of the functional safety assessment in the IT system. 
This publication is to be read in conjunction with IEC 61557-8:2007 and IEC 61557-9:2009
									
								
							
						
					Best Sellers From Electrical Sector
GSO 2530:2016
   
                        
                            
                            
                                Gulf Standard
                            
                        
                        
                            
                            
                                
                                Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
                            
                        
                        
                        OS GSO 2530:2016
   
                        
                            
                            
                                Omani Standard
                            
                        
                        
                            
                            
                                
                                Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
                            
                        
                        
                        OS GSO 34:2007
   
                        
                            
                            
                                Omani Standard
                            
                        
                        
                            
                            
                                
                                LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
                            
                        
                        
                        GSO 34:2007
   
                        
                            
                            
                                Gulf Technical Regulation
                            
                        
                        
                            
                            
                                
                                LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
                            
                        
                        
                        Recently Published from Electrical Sector
GSO IEC/IEEE 60214-2:2022
   
                        
                            IEC/IEEE 60214-2:2019 
                        
                        
                    
                            
                            
                                Gulf Standard
                            
                        
                        
                            
                            
                                
                                Tap-changers - Part 2: Application guidelines
                            
                        
                        
                        GSO IEC 60076-22-2:2022
   
                        
                            IEC 60076-22-2:2019 
                        
                        
                    
                            
                            
                                Gulf Standard
                            
                        
                        
                            
                            
                                
                                Power transformers - Part 22-2: Power transformer and reactor fittings - Removable radiators
                            
                        
                        
                        GSO IEC 60076-7:2022
   
                        
                            IEC 60076-7:2018 
                        
                        
                    
                            
                            
                                Gulf Standard
                            
                        
                        
                            
                            
                                
                                Power transformers - Part 7: Loading guide for mineral-oil-immersed power transformers
                            
                        
                        
                        GSO IEC 62841-2-4:2022
   
                        
                            IEC 62841-2-4:2014 
                        
                        
                    
                            
                            
                                Gulf Standard
                            
                        
                        
                            
                            
                                